Operations
Winterizing the Unit
1. Shut off the water supply. Disconnect the water
inlet hose from the front of your console.
2. Connect all high pressure solution hoses and tools
that may have water in them.
3. Start the unit. Open the tool valve until water pres-
sure drops and water stops flowing.
4. Turn off the engine.
5. Fill the water box with approximately two gallons of
100% glycol base anti-freeze.
6. Start the unit.
7. Open the tool valve until anti-freeze begins to
come out of the tool. Recover ALL anti-freeze that
comes out of the tools into an approved container.
We strongly recommend that you re-cycle and re-
use the anti-freeze.
Repeat this procedure with all the remaining tools. After
all tools and pressure hoses have been filled with anti-
freeze, disconnect and store them.
8. Turn off the unit. Attach the winterizing loop hose
with attachment, Part #86260700, to the solution
outlet connection and the water inlet connection.
9. Start the unit and allow it to run for approximately 3
minutes with the winterizing loop hose attached.
10. Open temperature control valve and allow anti-
freeze to flow to waste tank.
11. Prime the chemical system with 50/50 anti-freeze/
water mix. Insert the chemical inlet and prime dis-
charge tubes into the anti-freeze container. Turn
the chemical valve to PRIME until anti-freeze
begins to flow out of the prime hose.
12. Turn the chemical valve to the open position,
making certain that the flow meter indicates flow
and that all anti-freeze drains out of the chemical
hose into an approved container, after 30 seconds,
turn off both valves.